- Control Cables[10]
- Power Cables[10]
- Electrical Wires[10]
- Computer Cables & Connectors[7]
- Other Wires[10]
- Communication Cables[3]
- Contact Person : Mr. Lu Andy
- Company Name : Henan Huatai Special Cable Co., Ltd.
- Tel : 0086-371-86185038
- Fax : 0086-371-86185035
- Address : Henan,zhengzhou,No.8 Wanquanhe Road,Shangjie District,Zhengzhou,Henan,China
- Country/Region : China
- Zip : 450000
3.6/6, 6/10, 8.7/10kV Movable flexible rubber sheathed mining cable
1.Rated voltage Uo/U 1.9/3.3KV, 3.6/6KV and 6/10KV2.Long-term operating temperature of conductor is 90 o C3.The min. bevelling radius should be 6 times of cable outer diameter
Type | Description | Application |
UYPT MYPT-1.9/3.3 | Coal mining movable metallic shield rubber sheathed flexible cable | Connected power for movable coal mining equipment rated voltage upto 1.9/3.3KV |
UYP MYP-3.6/6 | Coal mining movable shield rubber sheathed flexible cable | Connected power for all kinds of movable coal mining equipment on the ground rated voltage upto 3.6/6KV,allowed ambient Min.temperature is -20 o C |
UYPT MYPT-3.6/6 | Coal mining movable metallic shield rubber sheathed flexible cable | |
UYDP MYDP-3.6/6 | Coal mining movable shield rubber sheathed flexible cable | Connected power for all kinds of movable coal mining equipment on the ground rated voltage upto 3.6/6KV,allowed ambient Min.temperature is -40 o C |
UYDPT MYDPT-3.6/6 | Coal mining movable metallic shield rubber sheathed flexible cable | |
UYP MYP-6/10 | Coal mining movable shield rubber sheathed flexible cable | Connected power for all kinds of movable coal mining equipment on the ground rated voltage upto 6/10KV,allowed ambient Min.temperature is -20 o C |
UYPT MYPT-6/10 | Coal mining movable metallic shield rubber sheathed flexible cable | Connected power for all kinds of movable coal mining equipment on the ground rated voltage upto 6/10KV,allowed ambient Min.temperature is -20 o C |
Specification:
NO.ominal cross-section of conductor mm 2 | Nominal Thickn mm | Outer diameter of cable mm | |||
Power core | Earthing core | Power core insulation | sheath | UYPT MYPT-1.9/3.3 | |
35 | 36/3 | 2.8 | 6.0 | 51.5-55.1 | |
30 | 35/3 | 2.8 | 6.0 | 52.0-56.8 | |
30 | 35/3 | 3.0 | 6.0 | 56.5-62.1 | |
35 | 30/3 | 3.0 | 6.0 | 62.0-68.2 |
NO.ominal cross-section of conductor mm 2 | Nominal Thickn mm | Outer diameter of cable mm | |||
Power core | Earthing core | Power core insulation | sheath | UYP MYP-3.6/6UYPT MYPT-3.6/6 | |
36 | 16 | 4.0 | 5.5 | 50.5-53.0 | |
35 | 16 | 4.0 | 5.5 | 54.3-59.7 | |
35 | 16 | 4.0 | 5.5 | 58.5-63.0 | |
30 | 15 | 4.0 | 5.5 | 62.5-67.7 | |
30 | 15 | 4.0 | 5.5 | 62.5-71.7 | |
35 | 10 | 4.0 | 5.5 | 67.5-76.8 | |
32 | 10 | 4.0 | 5.5 | 70.1-79.8 | |
35 | 10 | 4.0 | 5.5 | 76.0-86.3 |
3.6/6, 6/10, 8.7/10kV Movable flexible rubber sheathed mining cable